Mechanical Vapour Recompression for Ammonia Concentration

by | Apr 22, 2026 | Ammonia recovery

Mechanical Vapour Recompression for Ammonia Concentration

Mechanical vapour recompression (MVR) concentrates ammonium hydroxide by compressing the column’s own vapour and reusing its latent heat in the reboiler. For a design that raises ammonium hydroxide from 2% to 20% by weight, the working numbers were about 3,600 kg/h of vapour at 0.5 bar(a), a compressor lift to 0.9 bar(a), and roughly 2.3 MW of heat delivered to the reboiler for about 140 kW of shaft power.

The challenge: concentrating ammonia without a boiler

A dilute ammonia solution recovered from a stripping process is more valuable, and cheaper to transport, when it is stronger. Distilling it normally needs a steam supply. An MVR system avoids that by running the column under vacuum, so it boils at about 80°C, then compressing the vapour a little so that its condensing temperature is higher than the boiling liquid.

The approach: the numbers behind the loop

ItemValue
Column top pressure and temperature0.5 bar(a), about 80°C
Vapour flowabout 3,600 kg/h (water with a small ammonia content)
Compressor dischargeabout 0.9 bar(a), saturated at about 97°C
Temperature liftabout 15 to 20 K
Reboiler dutyabout 2.3 MW (for 4,000 kg/h of feed)
Estimated compressor shaft powerabout 140 kW
OperationContinuous, with turndown of 50 to 110%

Dividing 2.3 MW of heat by 140 kW of power gives a ratio of about 16 units of heat per unit of electricity. That is the appeal. A conventional approach would need around 2.3 MW of steam.

The compressor

The compressor handles water vapour with a little ammonia, so materials and seals must suit slightly ammoniacal vapour. The enquiry went to suppliers across Europe and China. It asked for a recommendation on how much liquid carry-over the compressor tolerates, what upstream mist separation is needed, the efficiency and noise, auxiliary systems such as lubrication and a variable speed drive, and whether the supplier could also supply the heat exchanger as a package.

The reboiler

The reboiler datasheet describes a shell-and-tube unit in 316L stainless steel with the following preliminary design:

  • Heat transfer area of about 250 to 260 m², based on an overall coefficient of 1,500 W/m²K and a log mean temperature difference of about 6 K.
  • About 900 tubes of 19 mm diameter and 5 m length, in two or four passes.
  • Condensing vapour on one side and boiling ammonia-bearing water on the other, with condensate going to a pot with level control and a vent.
  • Design to ASME VIII Division 1 or equivalent, with spiral wound or graphite gaskets suitable for ammonia.

The small temperature difference of 6 K is the reason for the large area. The smaller the lift, the less compressor power but the more exchanger surface.

Design reviews

The datasheet was reviewed by an engineer, and the comments are instructive: whether the exchanger should be a kettle type at all, which fluid belongs on which side, whether the fluid properties can be treated as clean water, whether a corrosion allowance is sensible on stainless tubes, and what test pressure the local rules require. These questions are normal for a first datasheet, and they were raised before any fabrication.

Why it works

The loop trades electricity for heat. Compressing the vapour raises its saturation temperature just enough to boil the column bottoms. Because the lift is small, the compressor is a low-pressure-ratio machine, such as a fan or a Roots-type blower, which is why the enquiry went to blower manufacturers as well as compressor makers.

What to consider for your own project

  1. Compare the economics with steam at your electricity and fuel prices.
  2. Minimise the lift. It sets the balance between compressor power and exchanger area.
  3. Protect the compressor from droplets, with a demister upstream.
  4. Choose materials for ammonia, including gaskets and seals.
  5. Treat the first datasheet as a draft. Reviews will change it.

For how the ammonia is first recovered, see our post on ammonia stripping waste heat.

FAQ

What is mechanical vapour recompression?

A process that compresses vapour to raise its temperature so it can heat the same process that produced it.

Why run the column under vacuum?

Lower pressure means a lower boiling temperature, so a smaller temperature lift is needed.

Is a fan or a compressor used?

At this pressure ratio, a high-volume fan or blower type machine can be used.

Why is the reboiler so large?

The temperature difference is only about 6 K, so a large area is needed to move 2.3 MW.

Concentrating ammonia?

Tell us your feed, product strength and utilities and we will outline the options.

Start your enquiry :


Translate »
organics.co.uk
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.