Gas Booster Station for Landfill Gas Engines, with a Standby Flare

by | Oct 1, 2025 | Landfill gas

Gas Booster Station for Landfill Gas Engines, with a Standby Flare

When landfill gas feeds engines, the gas booster is the heart of the system and the flare is the safety valve. A combined package pairs a high-head booster station, sized for the engines, with a smaller flare for gas the engines cannot take. This post uses a 2,500 m³/h booster at 300 mbar with a 500 m³/h ground flare, quoted for a power scheme in southern Europe, to show why the two are sized differently.

The challenge: engines need steady, pressurised gas

The enquiry was for a landfill gas power station. The booster had to deliver 2,500 m³/h at a total head of 300 mbar, with an inverter on the motor. The flare, by contrast, was 500 m³/h at 1,000°C. Options requested were an elevated flare instead of a ground flare, an acoustic enclosure around the booster, and a walk-in acoustic enclosure.

The flare is much smaller than the booster because it only handles surplus or off-spec gas, not the whole flow. The booster must instead meet the engines’ demand.

The approach

The booster station

Each booster sits on its own skid in its own GRP housing, with its own knockout pot. Key features:

  • Rated 2,500 Nm³/h at 300 mbar total head. The pressure head is the sum of suction and delivery pressure, so both must be known to size it correctly.
  • A stainless steel impeller, with a fully stainless steel booster as an upgrade, and an ExN (Zone 2) motor for outdoor use.
  • A variable speed drive, so absorbed power follows demand and the booster can be controlled manually or from a pressure transducer in the supply line.
  • A long-coupled, extended-shaft direct drive, so no belts to change.
  • A knockout pot with a liquid seal that holds up to about 360 mbar, with a polypropylene demister. The supplier advises against plastic knockout pots because they are flammable.
  • Instruments: outlet pressure switch, motor thermistor, knockout pot level switch, flashback temperature sensor, pressure gauges and an orifice-plate flow measurement point.

Pumping units of this type were described as achieving uptime above 99% to generators.

The flare

A standard 1,000°C enclosed ground flare with 0.3 seconds residence time, 5:1 turndown, 304 stainless steel combustion chamber and a spark-lit pilot. The control panel for the flare and flame arresters sits within the booster unit.

Optional extras

The enquiry priced an elevated flare in place of the ground flare, an acoustic cabinet around the booster only, and a walk-in acoustic enclosure. An optional oxygen sensor shuts the plant down above a set level, typically 8% in the UK and 6% in Germany. A methane analyser and carbon dioxide analyser help diagnose air ingress and field imbalance.

Why it works

The split lets each machine do one job. The booster is built for continuous service and tuned by the inverter. The flare is built for emissions and reliability but sized for a minority of the flow. The ground flare tends to be more compact in plan and quieter visually, while the elevated alternative costs less. The booster enclosure choice depends on noise limits.

What to consider for your own project

  1. Size the booster on the engines’ demand, including losses to the engine inlet.
  2. Use a variable speed drive to avoid wasting power.
  3. Size the flare on surplus, not the full flow, and check your permit.
  4. Plan noise attenuation early.
  5. See our booster post on sizing the gas booster.

FAQ

Why is the flare smaller than the booster?

It only burns gas the engines cannot use.

What is total head?

The sum of suction and delivery pressure that the booster must produce.

Why a variable speed drive?

It matches power to demand and controls start-up current.

Supplying gas to engines?

Tell us the engine demand and pipe layout and we will size the booster and flare.

Start your enquiry :


Translate »
organics.co.uk
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.